Just out todayAgritech: Texts to Ugandan farmers moved what they knew and what they thought, and not what they didArtificial intelligence: An AI trained on 142 cervical photographs reached an AUC of 0.70, and found the obvious casesUncategorized: Two satellites spotted wheat stem rust in Ethiopian plots before it was severe, and the blue band did the work

Uncategorized/Cameroon, Rwanda, Georgia, Greece, South Africa, Switzerland

Dried blood on filter paper found 97.2% of hepatitis C infections, and the card that separates plasma barely missed a negative

A four-country study found dried blood spots and plasma separation cards detect hepatitis C RNA almost as well as plasma, with the cards far more specific.

What the paper found

A multicentre study enrolled 936 participants in Cameroon, Rwanda, Georgia and Greece to test dried blood spots and plasma separation cards for hepatitis C RNA against plasma. Capillary dried blood spots reached 97.2% sensitivity and 88.6% specificity; capillary plasma separation cards reached 96.9% and 99.8%.

Grade 11 reading level7 min read

What happened

A team from FIND, the Centre Pasteur du Cameroun, Rwanda Military Hospital, Georgia’s National Center for Disease Control and Public Health, the University of Cape Town and the Rwanda Biomedical Center published a study of dried blood spot hepatitis C testing in PLOS Global Public Health.

The problem is logistical rather than scientific. A rapid antibody test tells you someone has met hepatitis C. It does not tell you whether the virus is still there, and antibodies persist after cure. So treatment requires an RNA test, and an RNA test normally requires plasma – which means a centrifuge, a cold chain and a laboratory.

Dried blood spots and plasma separation cards avoid all of that. Blood dries on filter paper, survives ambient temperatures, carries low biohazard risk and posts easily.

936 participants were enrolled in Cameroon, Rwanda, Georgia and Greece, drawn from three groups: people at risk of infection, people living with hepatitis C, and people previously treated for it. Capillary and venous blood were collected onto both card types and run on the Roche cobas 4800 and cobas 6800 platforms, with plasma on the same platforms as the reference standard.

Sensitivity never dropped below 95.2%. Specificity ranged from 87.8% to 99.8%, and the spread between those two numbers is the finding.

The test

This is a multicentre diagnostic accuracy study, and its structure deserves attention because diagnostic studies are easy to do badly.

Three design choices make this one credible. First, the reference standard was pre-specified: plasma run on the same platform. That isolates the variable of interest – the sample type – from assay and instrument differences. Second, three distinct populations were enrolled, including people previously treated, who are the hardest case because they carry antibodies without virus and are precisely where a specificity failure does damage. Third, four countries and six institutions, so the result does not rest on one laboratory’s handling.

The design’s limit follows from the same choice. Because plasma is the comparator rather than true infection status, the study measures agreement between sample types, not absolute accuracy. If the plasma assay itself misses something, both arms miss it together.

Both capillary and venous collection were tested. Capillary matters because it is a finger-prick, which is what makes community collection possible.

The numbers

Sample type Platform Sensitivity Specificity
Capillary dried blood spot cobas 4800 97.2% (95.2-98.3) 88.6% (85.4-91.2)
Venous dried blood spot cobas 4800 96.1% (93.9-97.5) 87.8% (85.4-90.4)
Venous plasma separation card cobas 4800 95.2% (92.8-96.8) 99.6% (98.5-99.9)
Venous dried blood spot cobas 6800 97.3% (95.4-98.5) 95.9% (93.7-97.3)
Venous plasma separation card cobas 6800 96.7% (94.6-98.0) 99.8% (98.8-100)
Capillary plasma separation card cobas 6800 96.9% (94.8-98.1) 99.8% (98.8-100)

Read the sensitivity column first: it is flat. Every combination lands between 95.2% and 97.3%, and the intervals overlap heavily. Sample type and platform make almost no difference to finding infections.

Now read the specificity column, which is not flat at all. Dried blood spots on the cobas 4800 sit near 88%. Plasma separation cards on either platform sit near 99.7%. That is a tenfold difference in false positives.

The result

Both card formats can replace plasma for finding hepatitis C infection. Only one of them can replace plasma for ruling it out.

A specificity of 88.6% means roughly eleven uninfected people in every hundred tested are flagged as positive. In a confirmatory test, which is what an RNA assay is, that is a serious cost: each false positive generates repeat testing, clinical time, and a patient told they have an active viral infection they do not have.

Plasma separation cards remove that problem almost entirely while giving up nothing measurable on sensitivity. The study’s practical conclusion is therefore narrower and more useful than “cards work”: if you are choosing a card, choose the one that separates plasma.

Moving from the cobas 4800 to the 6800 also lifted dried blood spot specificity from 87.8% to 95.9%, which suggests a meaningful part of the gap is assay handling rather than the sample itself.

How this compares to what came before

Set this beside the synthetic-data rapid-test interpretation work, which attacks a different link in the same chain – reading the test rather than transporting the sample.

The two together map where diagnostic access actually breaks in low-resource settings, and it is rarely the chemistry. It is the cold chain, the centrifuge, the courier and the person squinting at a faint line. This study removes the centrifuge and the cold chain; that one removes the squinting.

The pattern across both is worth stating plainly: the accessible version of a diagnostic usually loses specificity rather than sensitivity. Dried blood spots find almost every infection and over-call negatives. That is the predictable direction – a smaller, drier, more variable sample raises background – and it is why specificity is the number to check whenever a test is simplified for field use.

Against the dried blood spot literature generally, this study is unusually strong on population choice. Many validations recruit only known positives and healthy controls, which inflates both measures. Including previously treated patients is the hard test, and it is where the specificity gap showed up.

What it means

For a national hepatitis programme, this supports decentralising confirmatory testing to community collection with central laboratory analysis. That is a structural change in who can be diagnosed.

For procurement, the decision is specific: plasma separation cards cost more than filter paper and this study quantifies what the money buys, which is about eleven percentage points of specificity.

For clinicians, a positive dried blood spot RNA result on an older platform should not be treated as definitive in a previously treated patient.

Business ideas from this paper

Community collection logistics. The sample now survives ambient transport. The missing piece is the routing – collection points, batching, chain of custody, result return – and it is a service rather than a device.

Card manufacture and local supply. Plasma separation cards are the better-performing format and the more expensive one. Regional production against a demonstrated specificity advantage is a defensible position.

Result-return systems. Decentralised collection creates a new failure point: telling the person their result days later, somewhere other than a clinic. That is a messaging problem with measurable value attached.

What could be wrong with it

The reference standard was plasma on the same platforms, so this measures concordance between sample types rather than accuracy against true infection.

Not every sample-type and platform combination appears in the reported results. Capillary dried blood spots on the cobas 6800 are absent from the figures given, which makes a complete comparison impossible from the abstract alone.

Enrolment was weighted toward people at risk, living with, or previously treated for hepatitis C. In a general population with much lower prevalence, the same specificity produces a far worse positive predictive value.

The study does not report how many samples failed or were unusable, which is a central practical question for field collection.

Four countries is good geographic spread but each site contributes a modest number, and site-level variation in handling is not reported in the abstract.

How sure can you be?

Confident that dried blood spots and plasma separation cards detect hepatitis C RNA with sensitivity in the mid-nineties on both platforms. Six combinations, overlapping intervals, 936 participants, four countries.

Confident that plasma separation cards are substantially more specific than dried blood spots, with intervals that do not come close to overlapping.

Less confident about performance in a low-prevalence general screening population, which this enrolment cannot speak to.

Less confident about field feasibility, because sample failure rates are not reported.

Within our rubric’s range this sits in the upper band: a multicentre study with a pre-specified reference standard, independent sites in four countries, and the hard population included. It is scored as measurement against a reference standard, which is what it is, rather than as evidence about patient outcomes.

Do this today

If you are designing a hepatitis C testing pathway, specify the card type rather than the sampling concept. The two formats are not interchangeable and this study is the reason.

If you already run dried blood spot RNA testing, check which platform your laboratory uses. The specificity difference between the two here was eight percentage points.

Mark Alex

Mark Alex

Writes Just Out Tech. Founder and Managing Director of Real Biz Digital. Connect on LinkedIn.

Every article here is read against the paper it reports, and carries its own credibility score.

Source: Sensitivity and specificity of Dried Blood Spot and Plasma Separation Card samples for Hepatitis C Virus RNA Testing, PLOS Global Public Health, 2026-03-11. DOI 10.1371/journal.pgph.0006082 · doi.org ().

Just Out Tech explains new research in plain language. This article was drafted with AI assistance and checked by a human against the original source.

What to remember
  • 936 participants were enrolled across Cameroon, Rwanda, Georgia and Greece, in three populations: at risk, living with hepatitis C, and previously treated.
  • On the cobas 4800, capillary dried blood spots gave 97.2% sensitivity and 88.6% specificity.
  • Plasma separation cards were markedly more specific: 99.6% on the cobas 4800 and 99.8% on the cobas 6800.
  • Sensitivity never fell below 95.2% for any sample type or platform combination tested.
Where this really is

A multicentre diagnostic accuracy study on two commercial platforms with a plasma reference standard, conducted in four countries across three patient populations.

When it reaches you
Hepatitis C is curable, and the bottleneck between a positive antibody test and treatment is a laboratory. This study measures how much of that bottleneck can be removed by a piece of filter paper.
Who is building on it
The study evaluates Roche cobas 4800 and 6800 platforms and commercial card-based sampling. The sample types are not proprietary to a single supplier.
Who paid for the research
Not stated in the abstract; consult the paper's funding statement before citing a funder.
Our interest to declare
Authors include staff of FIND, a diagnostics non-profit. The platforms evaluated are Roche products; the paper carries a competing-interests statement.

Questions people ask

Why does hepatitis C need a second test at all?

A rapid antibody test shows exposure, not current infection. Antibodies persist after the virus clears or is cured, so treatment decisions require an RNA test that detects the virus itself.

Which sample type performed best?

Plasma separation cards. Sensitivity was comparable to dried blood spots, but specificity was far higher - 99.6% to 99.8% against 87.8% to 95.9% - meaning far fewer people wrongly told they have an active infection.

What does 88.6% specificity mean in practice?

Roughly eleven in a hundred uninfected people would be flagged as positive. In a screening programme that generates unnecessary confirmatory testing, cost and anxiety, which is why the card result matters more than the headline sensitivity.

Can these samples be collected outside a clinic?

That is the point. Dried blood spots and plasma separation cards can be collected in the community, carry low biohazard risk, tolerate ambient temperatures and are easy to store and ship, unlike plasma.

About the author

Mark Alex

Mark Alex is the founder and Managing Director of Real Biz Digital, a technology company operating out of Nairobi since 2018. He works in agentic AI and the Model Context Protocol, AI governance, enterprise software architecture and cybersecurity. He holds an MSc in Mechatronical Engineering from Obuda University in Budapest and a BSc in IT, Forensic Technology and Cybercrime, from USIU-Africa in Nairobi, and has published IEEE conference research on an AI-powered digital twin for greenhouse systems. He is the author of seven books. Between 2020 and 2024 he mentored more than 200 university students and interns in Nairobi. He writes every Just Out Tech article from the original research paper.